R8C/10 Group 19. Usage Notes
Rev.1.20 Jan 27, 2006 page 166 of 180
REJ09B0019-0120
19.3 Clock Generation Circuit
19.3.1 Oscillation Stop Detection Function
Since the oscillation stop detection function cannot be used if the main clock frequency is below
2MHz, set the OCD1 to OCD0 bits to 002 (oscillation stop detection function disabled).
19.3.2 Oscillation Circuit Constants
Ask the maker of the oscillator to specify the best oscillation circuit constants on your system.