M30870T-EPB User’s Manual 3. Usage (Emulator Debugger)
REJ10J0482-0300 Rev.3.00 February 16, 2006
(3) When DATA ACCESS is selected
1. Window for setting the address
2. Window for setting data
Setting the address
You can set eight conditions, e.g., a specified address, a
specified address range, etc.
Setting data
You can set eight conditions, e.g., a specified data, a
specified data range, etc.
Setting the access condition
You can set three conditions, e.g., read, write, an
d
read/write. When you have finished setting the data and
access condition, click OK.