13
Section 5 Diagnostic Test Procedure
This section describes the diagnostic test procedure using the E6000 test program.
5.1
5.15.1
5.1 System Set-Up for Test Program Execution
System Set-Up for Test Program ExecutionSystem Set-Up for Test Program Execution
System Set-Up for Test Program Execution
When executing the test program using the following hardware, do not connect the user system
interface cable and user system.
· E6000 (HS2339EPI61H)
· Host computer
· The E6000 PC interface board which will be one of the following boards or card:
Select one interface board from the following depending on the PC interface specifications.
ISA bus interface board (HS6000EII01H)
PCI bus interface board (HS6000EIC01H, HS6000EIC02H)
PCMCIA interface card (HS6000EIP01H)
1. Install the E6000 PC interface board in the host computer and connect the supplied PC
interface cable to the board.
2. Connect the PC interface cable to the E6000.
3. Connect the supplied AC adapter to the E6000.
4. Initiate the host computer to make it enter DOS prompt command input wait state.
5. Turn on the E6000 switch.
Vedere la pagina 29